KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 2 Basis - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90
Induction hob with integrated vapour extraction with Silence motor and 2 Flex zones for extraction mode
KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 2 Basis - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90
KMDA7272FL/FR, KMDA7473FL/FR -Installation variant 3 Basis - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90
KMDA7272FL, KMDA7473FL - Installation drawing
1) Front, 2) Removable drip tray, 3) Cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&Play operation: ≥10 mm - ≤40 mm
KMDA7272FL, KMDA7473FL - Side view lying on top, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm².
KMDA7272FL, KMDA7473FL - flush - Installation drawing
1) Front, 2) removable drip tray, 3) cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Step milling natural stone worktop, 6) Wooden strip 12 mm (not included in delivery), 7) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&play operation: ≥10 mm - ≤40 mm
KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 11 Exhaust air - drawing
1) DMK 150-1, 2) Flex hose
KMDA7272FL, KMDA7473FL - Side view flush, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the ventilation opening must be at least 425 cm².
KMDA7272FL, KMDA7473FL - Side view flush+X, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the carcase wall and an adjacent room wall or furniture. If the carcase rear wall is
KMDA7473FL/FR - Operating options
✓✓ Possible, ✓ Possible - further accessories necessary, - Programming must be changed - further accessories necessary
KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 9 Exhaust air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BH 90, 4) DFK-A, 5) DMK 150-1
KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 12 Exhaust air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BH 90, 4) DFK-A, 5) DMK 150-1
KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 1 Basis -drawing
1) DFK-AK 90, 2) DFK-R 1000
KMDA7272FL, KMDA7473FL - Side view lying on top+X, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the carcase wall and an adjacent room wall or furniture. If the carcase rear wall is
KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 10 Exhaust air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DMK 150-1
KMDA7272FL/FR, KMDA7473FL/FR, Exhaust air (Installation drawing)